Maintaining the correct refrigerant charge is crucial for cooling units. Monitoring and adjusting coolant levels is necessary, with various methods available depending on the system. Checking discharge and suction pressures, using level gauges or liquid level control cock, and observing gas leaving the evaporator are effective methods. Checking for excessive subcooling is also possible, but requires experienced technicians. Purging refrigerant should only be done as a last resort and not with harmful refrigerants.
Maintaining the correct refrigerant charge is a fundamental aspect for the correct functioning of a cooling unit. If the charge is too low, the evaporator capacity is reduced, and if it is too high, the excess could flow back into the condenser. Regardless of the type of cooling system you use, the best way to maintain the right coolant charge is to monitor it constantly and make adjustments when necessary. Depending on the type of system, the frequency of checks can vary, as well as the methods of verification.
The best way to maintain the refrigerant charge is largely based on the type of air conditioning system used. Ideally, the system has a means of indicating coolant levels directly. This is normally through level gauges or a liquid level control cock, depending on the age of the unit.
An effective method of checking coolant levels on all types of compression cooling equipment is to measure the discharge and suction pressures. Larger machines tend to have easily visible gauges that indicate evaporator and condenser pressures. Smaller machines may require manual testing.
In chillers, an evaporator liquid line sight glass will probably be the best way to check and maintain the refrigerant charge. If there are bubbles in the sight glass, then there is not enough refrigerant to keep the system line full enough. Bubbles aren’t a foolproof method, however, if the glass is upstream of a clogged filter.
When dealing with a direct expansion chiller system, refrigerant charge levels can only be verified by observing the gas leaving the evaporator. If there is a low charge, the gas will leave at high levels. The gas would be considered superheated.
In systems that have air-cooled condensers, such as heating, ventilation, and air conditioning (HVAC) systems, charging can be detected by checking for excessive subcooling of the refrigerant. Subcooling occurs when liquid refrigerant falls below its saturation temperature. This test is best done by experienced technicians because the temperature difference can be very subtle.
As a last resort in refrigerant charge monitoring, it is possible to purge the refrigerant from the system. After the operating pressure has dropped, more refrigerant can be added. This method should not be performed when using environmentally harmful refrigerants.