Factors limiting electricity transmission include distance, transmission power, materials, and location. Energy loss occurs during transmission due to Joule’s law and corona discharge. Thick cables and strategic additions like capacitor banks and transformers help manage power flow and minimize loss. Extension cords increase loss, limiting transmission.
There are several key factors that limit the transmission of electricity, such as the distance between the generator and the end user, the power of the original transmission, the material used to carry the electricity, and the location of the transmitters and capacitors. Each of these factors can limit the power of electricity for the end user. All of these problems must be closely monitored at all times to ensure safe transmission of electricity.
When energy is transmitted along a circuit, a certain percentage of the power is lost. This is due to the energy required to move electricity from the power generation source to the user. The rate of loss is defined in Joule’s law. This law states that the amount of energy lost is proportional to the squared value of the current voltage.
In order to ensure the supply of a certain level of electricity to the end user, electricity is transmitted at very high voltage. If the voltage is greater than 2,000 kilovolts, corona loss must be considered. Corona discharge loss is the amount of energy lost through the creation of an electric field that surrounds the power line as it carries electricity. This discharge occurs naturally and is the cause of the hum emitted by high voltage power lines. On average, there is an energy loss rate of 7.2% which can be attributed to the movement of electricity and this limits the transmission of electricity over long distances.
Electricity is transmitted using a series of high voltage cables to carry the electric current from the power generation station to a series of transformers. These cables are very thick and are designed to withstand the high amount of heat generated by the electricity as it moves through the cables. The heat threshold of cables is a factor limiting the transmission rates of electrical energy. As the volume of electricity carried along the wires increases, so does the temperature.
Power utilities typically add capacitor banks, phase shifting transformers, and phase conductors at strategic locations to control power flow, minimize power loss, and address known problems that limit electricity transmission. The length of uninterrupted power cables has been significantly reduced in an effort to manage the level of energy loss. This change has the added benefit of encouraging the development of a distributed electricity grid. This network reduces the risk of sustained power outages over a large area if a particular cable becomes damaged. The outage would be limited to a smaller area that can be served by an alternative power distribution line.
Once power is received on a household circuit, the electricity can be run along extension cords to increase the length of transmission. When energy is transmitted along the cable, a certain percentage of the power is lost. The loss is due to the energy required to travel along the distance from the generating source to the user and limits the transmission of electrical energy.
If the voltage of electric current in a circuit is 110 volts, the electric current lost is a factor of 10. To understand this concept, try the following experiment. Plug in a standard 100-foot (30.48-meter) power cord and plug it into a light fixture with a 100-watt light bulb. If you connect nine more 100-foot extension cords between the light fixture and the outlet, the total distance the electricity would have to travel is 30.4 meters by 1,000 feet. Because of the amount of electric current lost traveling this distance, there would not be enough energy available to light the 304.8 watt bulb.