What’s an Exit Door?

Print anything with Printful



Exit doors are regulated by local building codes, with NFPA guidelines in the US. Every door along the exit path is considered an exit door. NFPA standards are legally binding and updated every three years. Exit doors must meet specific requirements, including being unlockable with a single movement from inside. Exit doors are not the same as fire doors, which are designed to reduce the spread of flames and smoke during a fire.

An exit door is an exit designed to allow the occupants of a building to evacuate safely during an emergency. In most countries, these doors are regulated by local building codes, which stipulate how many doors are needed and the requirements for each exit. In the United States, most building codes for these doors are based on standards developed by the National Fire Protection Association (NFPA). NFPA 101 requires that an exit door must be operated, installed, and monitored. NFPA guidelines are based on building function and occupant load, as well as the presence of hazardous or combustible materials.

According to NFPA 101, an exit door is not limited to just an exit door that leads outdoors. Instead, every door along the building’s exit path is considered an exit door. This includes doors leading from various rooms to the exit, such as office or corridor doors located throughout the building. It also includes doors that lead to an exit, which often includes stairs or hall doors. Finally, the exit door itself, which allows occupants to move from the building to a public space, is also considered an exit door.

It is important to understand that the NFPA standards are not a law in and of themselves. However, once incorporated into a building code, they become legally binding on architects, contractors and condominium managers. Historically, the NFPA updates its standards at least every three years, but there is often a delay before the most recent version is adapted by each state or municipality.

An exit door must meet specific requirements before the building is approved by the local fire station or building inspector. All of these doors must be at least 32 inches (81 cm) wide in new buildings or at least 28 inches (71 cm) wide in existing structures. No single exit door may be wider than 48″ (121cm) because the size and weight of the door may slow evacuation. The door must also swing in the exit direction if the building has more than 50 occupants or if the building is at high risk of fire emergency.

When it comes to securing an exit door, all locks must be unlockable with a single movement from inside the room. This means that a separate deadbolt and latchbolt are not acceptable, as they would require more than one action to unlock. Double-sided bolts are also unacceptable because they can’t always be unlocked from within the space. All locking devices must allow re-entry into the building from a stairwell and no chains, bolts or bars must be placed on the door when the building is occupied.

An exit door is not the same as a fire door. A fire opening is designed to reduce the spread of flames and smoke during a fire. It features a fire resistant core and special hardware to ensure it stays closed and locked during a fire. Exit doors are designed to allow for quick and safe exit during any type of emergency. They may or may not be fire resistant and are used to allow as many people as possible to exit without panic or injury.