Suction pressure is the refrigerant gas pressure at the compressor’s suction point in air conditioning and refrigeration. It plays a crucial role in system operation and diagnosis, with a balance between suction and discharge pressure being necessary for proper function. Suction pressure can be used as a diagnostic aid, with abnormal values indicating potential faults. The misconception that air conditioners blow cold air is addressed, with the refrigeration cycle explained.
Suction pressure is a term used to describe the pressure of a refrigerant gas at the suction point of a refrigerator or air conditioner compressor. Suction or, as it is also known, lateral low pressure, is one of the critical variants in the operational and diagnostic processes of air conditioning and refrigeration. A proper balance between suction and discharge pressure ensures that the system is healthy and functioning properly. This relationship, together with the suction and discharge temperatures and the specific refrigerant used, plays an important role in determining the correct refrigerant charges for individual systems.
Suction pressure refers to the pressure of the refrigerant at the point where it enters the compressor after leaving the building interior. Measured when the compressor is running, this pressure will typically be on the order of 100 pounds per square inch (PSI). The exact inlet pressure that an air handling unit is designed to produce is a product of the expected capacity of the system, the specific components employed, and the refrigerant that the system is designed to use.
A commonly held misconception is that an air conditioner blows cold air into a room or building. All refrigeration systems operate on a basic heat transfer principle where cold, low pressure refrigerant circulates through a series of coiled tubes within the area to be cooled. This cold fluid absorbs heat from the atmosphere in the room and is then pumped out of the building via the system’s compressor where a fan or water spray dissipates the heat. The refrigerant is then returned to the interior of the building to repeat the process until the desired temperature is reached.
The relationship between the compressor suction and outlet pressures and temperatures are known quantities in a given air conditioning or refrigeration system. This finite relationship allows the inlet pressure values to be used as a diagnostic aid when troubleshooting the system. For example, high suction pressure can indicate a clogged condenser coil or a faulty condenser fan. Low pressure readings, on the other hand, can be an indication of a refrigerant undercharge or restricted internal airflow.
This general overview of a refrigeration cycle serves to demonstrate the importance of suction pressure. For any air conditioning or refrigeration system to function properly, the ratio of low to high lateral pressure must be kept within the operating specifications of the system. Abnormal values of inlet pressure can, however, be a very reliable indication of where the faults lie in systems that are not working properly.